歡迎訪問(wèn)中科光析科學(xué)技術(shù)研究所官網(wǎng)!

免費(fèi)咨詢熱線
400-640-9567|
全無(wú)油潤(rùn)滑高壓往復(fù)活塞氧氣壓縮機(jī)檢測(cè)項(xiàng)目報(bào)價(jià)???解決方案???檢測(cè)周期???樣品要求? |
點(diǎn) 擊 解 答??![]() |
本規(guī)范適用于新建、改建、擴(kuò)建的有色金屬礦山預(yù)可行性研究、可行性研究和礦山工程建設(shè)的采礦設(shè)計(jì)。
本規(guī)范為企業(yè)的設(shè)備檢修提供指導(dǎo)意見(jiàn),可作為企業(yè)制定設(shè)備檢修細(xì)則、檢修操作規(guī)程和設(shè)備完好標(biāo)準(zhǔn)的依據(jù)。本規(guī)范執(zhí)行《煤炭法》、《礦山安全法》、《煤礦安全監(jiān)察條例》、《煤礦安全規(guī)程》等煤炭法律、法規(guī)、規(guī)程和管理標(biāo)準(zhǔn),執(zhí)行和有關(guān)煤炭行業(yè)的所有技術(shù)標(biāo)準(zhǔn)。本規(guī)范通用部分的技術(shù)要求和計(jì)量單位等執(zhí)行或有關(guān)行業(yè)的技術(shù)標(biāo)準(zhǔn)。
本規(guī)程適用于建筑施工中各類建筑機(jī)械的使用與管理。
本規(guī)范適用于新建、擴(kuò)建和改建的工業(yè)與民用建筑及市政工程施工現(xiàn)場(chǎng)機(jī)械設(shè)備的檢查。
本標(biāo)準(zhǔn)規(guī)定了全無(wú)油潤(rùn)滑高壓往復(fù)活塞氧氣壓縮機(jī)(以下簡(jiǎn)稱氧壓機(jī))的基本參數(shù)、技術(shù)要求、試驗(yàn)方法、檢驗(yàn)規(guī)則、標(biāo)志、包裝和貯存。本標(biāo)準(zhǔn)適用于進(jìn)氣壓力為0.002 MPa~0.4 MPa、額定排氣壓力為15.0 MPa、公稱容積流量不大于100 m<上標(biāo)3>/h(標(biāo)準(zhǔn)狀態(tài))的氧壓機(jī)。不在本標(biāo)準(zhǔn)范圍內(nèi)的氧壓機(jī),可參照本標(biāo)準(zhǔn)執(zhí)行。
本標(biāo)準(zhǔn)規(guī)定了火力發(fā)電廠熱控系統(tǒng)檢修運(yùn)行維護(hù)的內(nèi)容、方法和技術(shù)管理應(yīng)達(dá)到的標(biāo)準(zhǔn)。本標(biāo)準(zhǔn)適用于火力發(fā)電廠已投產(chǎn)機(jī)組熱控系統(tǒng)的檢修和日常運(yùn)行維護(hù)工作。
本標(biāo)準(zhǔn)規(guī)定了建筑工人安全操作的術(shù)語(yǔ)和定義、總則、一般規(guī)定、架子工、瓦工、抹灰工、石工、木工、鋼筋工、混凝土工、普通工、電工、安裝電工、防水工、起重吊裝工、金屬焊割作業(yè)工、油漆工、測(cè)量工、機(jī)械設(shè)備維修工、水暖工、鉚工、通風(fēng)工、筑爐工、保溫工、樁基施工、大模片施工、鋼結(jié)構(gòu)及網(wǎng)架施工、裝飾裝修施工、拆除施工、土方及筑路機(jī)械、樁工機(jī)械、吊裝及垂直運(yùn)輸機(jī)械、混凝土機(jī)械、中小型施工機(jī)具、市政工程的操作。
This part of EN 1012 is applicable to compressors having an operating pressure greater than 0,5 bar and designed to utilise all gases other than air, nitrogen or inert gases which are covered in part 1. The standard lists the significant hazards associated with compressors and specifies safety requirements applicable to the design, installation, operation, maintenance and dismantling of compressors during their foreseeable lifetime and subsequent disposal.This part of EN 1012 includes under the general term compressors, those machines which comprise;- the compressor itself- a prime mover- any component or device supplied which is necessary for safe operation of the compressor.In addition it applies to partly completed compressors having a compressor in combination with some of these components as well as compressor assemblies operating in combination.Excluded are refrigerant compressors used in refrigerating systems or heat pumps as defined in EN 378-1.
This European Standard describes the specific functional requirements for the design, construction, operation, maintenance and disposal activities for safe and secure gas compressor stations. This European Standard applies to new gas compressor stations with a Maximum Operating Pressure (MOP) over 16 bar and with a total shaft power over 1 MW. For existing compressor stations, this European Standard applies to new compressor units. Where changes/modifications to existing installations take place, due account may be taken of the requirements of this European Standard. This European Standard does not apply to gas compressor stations operating prior to the publication of this European Standard. The purpose of this European Standard is intended to: - ensure the health and safety of the public and all site personnel, - to cover environmental issues and - to avoid incidental damage to nearby property. This European Standard specifies common basic principles for the gas infrastructure. Users of this European Standard should be aware that more detailed national standards and/or codes of practice may exist in the CEN member countries. This European Standard is intended to be applied in association with these national standards and/or codes of practice setting out the above-mentioned basic principles. In the event of conflicts in terms of more restrictive requirements in national legislation/regulation with the requirements of this European Standard, the national legislation/regulation takes precedence as illustrated in CEN/TR 13737 (all parts). CEN/TR 13737 (all parts) gives: - clarification of all legislations/regulations applicable in a member state; - if appropriate, more restrictive national requirements; - a national contact point for the latest information. This European Standard does not apply to: - off-shore gas compressor stations; - gas compressor stations for compressed natural gas filling-stations; - customer installations downstream of the point of custody trans
This British Standard gives recommendations for, and guidance on,the design for the installation of instrumentation of measurementand control systems in the process industry, and the implementationand commissioning of this installation. It is intended to be used asa manual of good practice on the site and also to assist those whodesign the installation.
前沿科學(xué)
微信公眾號(hào)
中析研究所
抖音
中析研究所
微信公眾號(hào)
中析研究所
快手
中析研究所
微視頻
中析研究所
小紅書